Electromagnet before 2019-09-10 =============================== This page lists the parameters of the first version of the FFT electromagnet that was installed in the FFT end-station from the start of SCS operation up to the 10th of September 2019 when an improved version was put in place instead. .. _electromagnet_field: .. figure:: electromagnet-field.png Magnetic field as function of current in the electromagnet. From `elog 270`_. ======= ======= ===== Voltage Current Field V A mT ======= ======= ===== 0 0 4 1 1.3 50 2 2.6 98 3 4 150 4 5.3 200 5 6.5 250 6 7.7 283 7 9 315 8 10 335 9 11.1 355 10 12.2 362 ======= ======= ===== .. _electromagnet_temperature: .. figure:: electromagnet-temperature.png Temperature of the electromagnet for different settings. From `elog 270`_. The magnetic field generated by the electromagnet is shown in :numref:`electromagnet_field`. ===================== =================== ================= gap between pole (mm) maximum current (A) maximum field (T) ===================== =================== ================= 7.7 12 0.37 ===================== =================== ================= The temperature reached near the coil winding edge on the pole is shown in :numref:`electromagnet_temperature`. Combination of 5°C cooling and high water flow-rate should keep the coil temperature <50°C when operating at 12 A in vacuum. The geometry of the pole shoe is defined in `CAD file`_. .. _elog 270: https://in.xfel.eu/elog/SCS+Beamline/270 .. _CAD file: https://docs.xfel.eu/share/page/site/xfelwp86/document-details?nodeRef=workspace://SpacesStore/10c07bd4-0dce-419f-b3c6-db51d614a2a1