BeckhoffPfeifferTCDriveUnit

Commands

Key Displayed Name Description Alias Access Level Allowed States
disablePumpingStation Disable Pumping Station
Disables the pumping station
COff USER STOPPED, INTERLOCK_BROKEN
enablePumpingStation Enable Pumping Station
Enables the pumping station (does not start
pumping yet)
COn USER OFF, STOPPED, INTERLOCK_BROKEN
startPumping Start Pumping
Starts the pump
CPump USER STOPPED, INTERLOCK_BROKEN
stopPumping Stop Pumping
Stops the pump
CStop USER STARTED, INTERLOCK_BROKEN
remotePriorityOff Remote Priority Off
Disable remote control
CRemotePriorityOff EXPERT STOPPED, STARTED, ERROR, OFF, INTERLOCK_BROKEN
remotePriorityOn Remote Priority On
Enable remote control
CRemotePriorityOn EXPERT STOPPED, STARTED, DISABLED, ERROR, OFF, INTERLOCK_BROKEN
resetController Reset Controller Error
reset error on controller
CResetCtrl EXPERT ERROR, INTERLOCK_BROKEN
startHeating Start Heating
Start Heating
CHeat EXPERT STOPPED, STARTED, INTERLOCK_BROKEN
startStandby Start Standby
Start Standby operation
CStandby EXPERT STOPPED, STARTED, INTERLOCK_BROKEN
startVenting Start Venting
Start Venting
CVenting EXPERT STOPPED, STARTED, INTERLOCK_BROKEN
stopHeating Stop Heating
Stop Heating
CStopHeat EXPERT STOPPED, STARTED, INTERLOCK_BROKEN
stopStandby Stop Standby
Stop Standby operation
CStopStandby EXPERT STOPPED, STARTED, INTERLOCK_BROKEN
stopVenting Stop Heating
Stop Heating
CStopVenting EXPERT STOPPED, STARTED, INTERLOCK_BROKEN

Properties

Key Displayed Name Description Alias Type Access Level Access Mode Allowed States
isRPMExceed isRPMExceed
isRPMExceed
  Bool OBSERVER READONLY  
remotePriority Remote Priority
Remote priority.
ARemotePriority Bool OBSERVER READONLY  
standbyOnOff Standby On/Off
Standby On/Off.
AStandby Bool OBSERVER READONLY  
actualRotationSpeed Actual Rot. Speed
Actual rotation speed.
AActualRotSpeed UInt32 OPERATOR READONLY  
actualRotationSpeedRpm Actual Rot. Speed
Actual rotation speed [rpm].
AActualRotSpeedrpm UInt32 OPERATOR READONLY  
driveCurrent Drive Current
Drive current.
ADriveCurrent Float OPERATOR READONLY  
driveVoltage Drive Voltage
Drive voltage.
ADriveVoltage Float OPERATOR READONLY  
errorCode Error Code
Error code.
AErrorCode String OPERATOR READONLY  
temperatureBearing Temp Bearing
Temperature bearing.
ATemperatureBearing UInt32 OPERATOR READONLY  
temperatureElectronic Temp Electronics
Temperature electronics.
ATemperatureElectronic UInt32 OPERATOR READONLY  
temperatureMotor Temp Motor
Temperature motor.
ATemperatureMotor UInt32 OPERATOR READONLY  
acceleration Acceleration
Acceleration [rpm/s].
AAcceleration UInt32 EXPERT READONLY  
accessoryConnectionA1 Accessory Conn. A1
Accessory connection A1: 0 = Fan (continuous
operation); 1 = Venting valve, normally closed;
2 = Heating; 3 = Backing pump; 4 = Fan
(temperature controlled); 5 = Sealing gas; 6 =
always 0; 7 = always 1; 8 = Power failure
venting unit.
ACfgAccessoryConnA1 UInt16 EXPERT RECONFIGURABLE  
accessoryConnectionA2 Accessory Conn. A2
Accessory connection A2: 0 = Fan (continuous
operation); 1 = Venting valve, normally closed;
2 = Heating; 3 = Backing pump; 4 = Fan
(temperature controlled); 5 = Sealing gas; 6 =
always 0; 7 = always 1; 8 = Power failure
venting unit.
ACfgAccessoryConnA2 UInt16 EXPERT RECONFIGURABLE  
accessoryConnectionB1 Accessory Conn. B1
Accessory connection B1: 0 = Fan (continuous
operation); 1 = Venting valve, normally closed;
2 = Heating; 3 = Backing pump; 4 = Fan
(temperature controlled); 5 = Sealing gas; 6 =
always 0; 7 = always 1; 8 = Power failure
venting unit.
ACfgAccessoryConnB1 UInt16 EXPERT RECONFIGURABLE  
accessoryConnectionB2 Accessory Conn. B2
Accessory connection B2: 0 = Fan (continuous
operation); 1 = Venting valve, normally closed;
2 = Heating; 3 = Backing pump; 4 = Fan
(temperature controlled); 5 = Sealing gas; 6 =
always 0; 7 = always 1; 8 = Power failure
venting unit.
ACfgAccessoryConnB2 UInt16 EXPERT RECONFIGURABLE  
backingPump Backing Pump
Operation mode backing pump: 0 = Continuous; 1
= Intermittend; 2 = Delayed switch on
AOperationModeBackingPump UInt16 EXPERT RECONFIGURABLE  
baudRate Baud Rate
Baud Rate: 1=300 2=600 3=1200 4=2400 5=4800
6=9600 7=19200 8=38400 9=57600 10=115200 Baud.
ABaudRate UInt8 EXPERT RECONFIGURABLE  
bufferFull Buffer Full
Buffer Full Notification.
ABufFull Int16 EXPERT RECONFIGURABLE  
configDO1 Config. DO1
Configure DO1: 0 = Rot. speed switch point
attained; 1 = No error; 2 = Error; 3 = Warning
4 = Error and/or warning; 5 = Set speed
attained; 6 = Pump on; 7 = Pump accelerates; 8
= Pumpe decelerates 9 = always 0; 10 = always
1; 11 = Remote priority active; 12 = Heating;
13 = Backing pump 14 = Sealing gas; 15 =
Pumping station
AConfigDO1 UInt16 EXPERT RECONFIGURABLE  
configDO2 Config. DO2
Configure DO2: 0 = Rot. speed switch point
attained; 1 = No error; 2 = Error; 3 = Warning
4 = Error and/or warning; 5 = Set speed
attained; 6 = Pump on; 7 = Pump accelerates; 8
= Pumpe decelerates 9 = always 0; 10 = always
1; 11 = Remote priority active; 12 = Heating;
13 = Backing pump 14 = Sealing gas; 15 =
Pumping station
AConfigDO2 UInt16 EXPERT RECONFIGURABLE  
configInputDI1 Config. Input DI1
Configure Input DI1: 0 = Deactivated; 1 =
Enable venting; 2 = Heating; 3 = Sealing gas; 4
= Run-up time control; 5 = Rotation speed
setting mode; 6 = Motor.
AConfigInputDI1 UInt16 EXPERT RECONFIGURABLE  
configInputDI2 Config. Input DI2
Configure Input DI2: 0 = Deactivated; 1 =
Enable venting; 2 = Heating; 3 = Sealing gas; 4
= Run-up time control; 5 = Rotation speed
setting mode; 6 = Motor.
AConfigInputDI2 UInt16 EXPERT RECONFIGURABLE  
configOutputA01 Config Output A01
Configure output AO1: 0 = Actual rotation
speed; 1 = Power; 2 = Current; 3 = always 0 V;
4 = always 10 V.
AConfigOutputAO1 UInt16 EXPERT RECONFIGURABLE  
controlInterface Control Interface
Control interface: 1 = Remote; 2 = RS485; 4 =
PV.can; 8 = Field bus; 16 = E74; 255 = Unlock
interface selection.
AControlViaInterface UInt16 EXPERT RECONFIGURABLE  
dataFrame Data Frame
Data Frame: 1=7E1 2=7O1 3=8N1 4=8E1 5=8O1 9=7E2
10=7O2 11=8N2 12=8E2 13=8O2.
ADataFrame UInt8 EXPERT RECONFIGURABLE  
drivePower Drive Power
Drive power.
ADriverPower UInt32 EXPERT READONLY  
driveUnitName Drive Unit Name
Name of the electronic drive unit.
ANameDriveUnit String EXPERT READONLY  
enableFifoCont Enable FIFO Cont.
Enable send FIFO data continuous
AFifoCont Bool EXPERT RECONFIGURABLE  
enableRtsCts Enable RTS/CTS
Enable RTS/CTS
ARtsCts Bool EXPERT RECONFIGURABLE  
enableTransferOpt Enable Transfer Rate Opt.
Enable transfer rate optimization
ATransferOpt Bool EXPERT RECONFIGURABLE  
enableVenting Enable Venting
Enable venting.
AEnableVenting Bool EXPERT READONLY  
enableXonXoffRx Enable XOn/XOff Rx
Enable XOn/XOff supported rx data
AXonXoffRx Bool EXPERT RECONFIGURABLE  
enableXonXoffTx Enable XOn/XOff Tx
Enable XOn/XOff supported tx data
AXonXoffTx Bool EXPERT RECONFIGURABLE  
errorAck Error Ack
Error Acknowledgment.
AErrorAck Bool EXPERT RECONFIGURABLE  
errorCodeHistory1 Err Code History 1
Error code history 1.
AErrorCodeHistory1 String EXPERT READONLY  
errorCodeHistory10 Err Code History 10
Error code history 10.
AErrorCodeHistory10 String EXPERT READONLY  
errorCodeHistory2 Err Code History 2
Error code history 2.
AErrorCodeHistory2 String EXPERT READONLY  
errorCodeHistory3 Err Code History 3
Error code history 3.
AErrorCodeHistory3 String EXPERT READONLY  
errorCodeHistory4 Err Code History 4
Error code history 4.
AErrorCodeHistory4 String EXPERT READONLY  
errorCodeHistory5 Err Code History 5
Error code history 5.
AErrorCodeHistory5 String EXPERT READONLY  
errorCodeHistory6 Err Code History 6
Error code history 6.
AErrorCodeHistory6 String EXPERT READONLY  
errorCodeHistory7 Err Code History 7
Error code history 7.
AErrorCodeHistory7 String EXPERT READONLY  
errorCodeHistory8 Err Code History 8
Error code history 8.
AErrorCodeHistory8 String EXPERT READONLY  
errorCodeHistory9 Err Code History 9
Error code history 9.
AErrorCodeHistory9 String EXPERT READONLY  
firmwareVersion Firmware Version
Firmware version drive unit.
AFirmwareVersDriveUnit String EXPERT READONLY  
gasMode Gas Mode
Gas Mode: 0 = Heavy; 1 = Light; 2 = Helium.
AGasMode UInt16 EXPERT RECONFIGURABLE  
heatingOnOff Heating On/Off
Heating On/Off.
AHeating Bool EXPERT READONLY  
hwVersionDriveUnit HW Version
Hardware version of electronic drive unit.
AHWVersionDriveUnit String EXPERT READONLY  
interfaceSelectionLocked Lock Interface Selection
Lock interface selection.
AInterfaceSelectionLocked Bool EXPERT RECONFIGURABLE  
motorPump Motor Pump
Motor pump.
AMotorPump Bool EXPERT READONLY  
nominalRotationSpeed Nominal Rot. Speed
Nominal rotation speed.
ANominalSpeed UInt32 EXPERT READONLY  
nominalRotationSpeedConfirmation Nominal Rot. Speed Confirmation
Confirmation of nominal rotation speed.
ANominalRotSpdConfirmation UInt32 EXPERT RECONFIGURABLE  
nominalRotationSpeedRpm Nominal Rot. Speed
Nominal rotation speed [rpm].
ANominalSpeedrpm UInt32 EXPERT READONLY  
operatingHoursDriveUnit Operating Hours Drive Unit
Operating hours drive unit.
AOperatingHourDriveUnit UInt32 EXPERT READONLY  
operatingHoursPump Operating Hours Pump
Operating hours pump.
AOperatingHoursPump UInt32 EXPERT READONLY  
overtTempDriveUnit Over Temp Drive Unit
Over temperature drive unit.
AOverTempDriveUnit Bool EXPERT READONLY  
overtTempPump Over Temp Pump
Over temperature pump.
AOverTempPump Bool EXPERT READONLY  
powerConsumptionValue Power Consumption Value
The value of power consumption.
AValuePowerConsumption UInt16 EXPERT RECONFIGURABLE  
pumpAccelerates Pump Accelerates
Pump accelerates.
APumpAccelerates Bool EXPERT READONLY  
pumpCycles Pump Cycles
Pump cycles.
APumpCycles UInt32 EXPERT READONLY  
pumpingStationOnOff Pumping station On/Off
Pumping station On/Off.
APumpingStation Bool EXPERT READONLY  
rotationSpeedDelayedVenting Venting Rot. Speed @ Delayed Venting
The venting rotation speed at delayed venting.
AVentRotSpdDelayedVenting UInt16 EXPERT RECONFIGURABLE  
rotationSpeedSettingMode Rotation Speed Set Mode
Rotation speed setting mode: 0 = Off; 1 = On.
This setting is needed for Standby operation.
ARotSpeedSettingMode UInt16 EXPERT RECONFIGURABLE  
rotationSpeedSettingModeValue Rot. Speed Setting Mode Value
The value of the rotation speed setting mode.
AValueRotSpdSettingMode Float EXPERT RECONFIGURABLE  
rotationSpeedStandBy Rot. Speed Stand-By
The rotation speed at stand-by.
ARotationSpeedStandby Float EXPERT RECONFIGURABLE  
rotationSpeedSwitchPointAttained Rot. Speed Switchpoint Attained
Rotation speed switch point attained.
ARotationSpdSwPtAttained Bool EXPERT READONLY  
rotationSpeedSwitchpoint Rot. Speed Switch Point
Rotation speed switch point: 0 = switch point 1
only; 1 = switch points 1 and 2.
ACfgRotationSpeedSwitchpoint UInt16 EXPERT RECONFIGURABLE  
rotationSpeedSwitchpoint1 Rot. Speed Switch Point 1
The rotation speed switch point 1.
ARotSpdSwitchPoint1 UInt32 EXPERT RECONFIGURABLE  
rotationSpeedSwitchpoint2 Rot. Speed Switch Point 2
The rotation speed switch point 2.
ARotSpdSwitchpoint2 UInt32 EXPERT RECONFIGURABLE  
rs485DeviceAddress RS485 Device Address
The address of the RS485 device.
ARS485DeviceAdress UInt32 EXPERT RECONFIGURABLE  
runUpTimeOnOff Run-Up Time
Run-up time control
ARunUpTimeControl Bool EXPERT RECONFIGURABLE  
sealingGasOnOff Sealing Gas
Sealing gas On/Off.
ASealingGas Bool EXPERT RECONFIGURABLE  
serialCheck Serial Check
Check serial protocol command value (reads back
string from command function window (ASerP
input value)
ASerCheck String EXPERT RECONFIGURABLE  
serialString Serial String
Send serial string.
ASerial String EXPERT RECONFIGURABLE  
setRotationSpeed Set Rot. Speed
Set rotation speed.
ASetRotSpeed UInt32 EXPERT READONLY  
setRotationSpeedRpm Set Rot. Speed
Set rotation speed [rpm].
ASetRotSpeedrpm UInt32 EXPERT READONLY  
setSpeedAttained Set Speed Attained
Set speed attained.
ASetSpeedAttained Bool EXPERT READONLY  
switchOffThresholedBKP Switch Off Threshold BKP
Switching off threshold backing pump in
intermittent mode.
ASwoffThresholdBKP UInt16 EXPERT RECONFIGURABLE  
switchOnThresholedBKP Switch On Threshold BKP
Switching on threshold backing pump in
intermittent mode.
ASwonThresholdBKP UInt16 EXPERT RECONFIGURABLE  
targetRunupTime Set Value Run-Up Time
The run-up time set value.
ASetValueRunUpTime UInt32 EXPERT RECONFIGURABLE  
temperaturePumpBottom Temp Pump Bottom
Temperature pump bottom part.
ATemperaturePumpBottom UInt32 EXPERT READONLY  
ventingMode Venting Mode
Venting mode: 0 = Delayed Venting; 1 = No
Venting; 2 = Direct Venting.
AVentingMode UInt16 EXPERT RECONFIGURABLE  
ventingTimeDelayedVenting Venting Time @ Delayed Venting
The venting time at delayed venting.
AVentTimeDelayedVenting UInt32 EXPERT RECONFIGURABLE