BeckhoffBronkhorst

Commands

Key Displayed Name Description Alias Access Level Allowed States
softReset Soft Reset
Soft
Reset
  USER  

Properties

Key Displayed Name Description Alias Type Access Level Access Mode Allowed States
IOStatus IO Status

AIOStatus UInt8 EXPERT RECONFIGURABLE  
PIDKp PID Kp
PID factor Kp
APIDKp Float EXPERT RECONFIGURABLE  
PIDTd PID Td
PID factor Td
APIDTd Float EXPERT RECONFIGURABLE  
PIDTi PID Ti
PID factor Ti
APIDTi Float EXPERT RECONFIGURABLE  
analogInFullScale Analog Input Full Scale
Analog Input correction factor full scale (2000
a.u. = 1 V * Multiplication)
AAnalogInputFullScale Int16 EXPERT RECONFIGURABLE  
analogInZeroScale Analog Input Zero Scale
Analog Input correction factor zero scale
AAnalogInputZeroScale Int16 EXPERT RECONFIGURABLE  
analogInput Analog Input
Measurement expressed in arbitrary units 32000
is 100%
AAnalogInput Int16 EXPERT READONLY  
analogOutFullScale Analog Output Full Scale
Analog Output correction factor full scale
(2000 a.u. = 1 V * Multiplication)
AAnalogOutputFullScale Int16 EXPERT RECONFIGURABLE  
analogOutZeroScale Analog Output Zero Scale
Analog Output correction factor zero scale
AAnalogOutputZeroScale Int16 EXPERT RECONFIGURABLE  
analogSetPointFullScale Analog Setpoint Full Scale
analog setpoint output correction factor full
scale (2000=1*multiplication)
AAnSetpntInputFullScale Int16 EXPERT RECONFIGURABLE  
analogSetPointZeroScale Analog Setpoint Zero Scale
analog V ref. input corr. factor zero scale
(DSCM-A 0=0 other 32767=0)
AAnSetpntInputZeroScale Int16 EXPERT RECONFIGURABLE  
calibrationCertificate Calibration Certificate
Number of calibration certificate (last basic
calibration)
ACalibrationCertificate String EXPERT RECONFIGURABLE  
calibrationDate Calibration Date
Date of last (basic) calibration (e.g.
19991231)
ACalibrationDate String EXPERT RECONFIGURABLE  
calibrationMode Calibration Mode
Calibration Mode : 0=(idle: no action) 1=(adc
self calibration) 2=(dmfc) 3=(dmfc) 4=(dmfc)
5=(dmfc) 6=(dmfc) )7=(dmfc) 8=(dmfc)
)9=(customer zero) 10=(adjust Vref output by
connecting it to analog in) 11=(adjust analog
out by connecting it to analog in) 12=(adjust
valveoutput by connecting it to analog in)
13=(dmfc) 14=(dmfc) 15=(analog output = 0 %)
16=(analog output = 100 %) 17=(analog output =
50 %) 18=(factory zero) 19=(sensor
differentiator (setpoint steps are needed!))
20=(automatic sensor configuration) 21=(sensor
temperature calibration) 22=(customer zero (no
control mode 9 needed)) 255=(Error mode (result
of previous cal mode))
ACalibrationMode UInt8 EXPERT RECONFIGURABLE  
capacity Capacity
Capacity
ACapacity Float EXPERT RECONFIGURABLE  
capacity0Percent Capacity 0 Percent
capacity 0 Percent
ACapacity0Percent Float EXPERT RECONFIGURABLE  
capacityUnit Capacity unit
Capacity unit
ACapacityUnit String EXPERT READONLY  
capacityUnitIndex capacityUnitIndex

ACapacityUnitIndex UInt8 EXPERT RECONFIGURABLE  
comm.baudRate Baud Rate
Baud Rate: 1=300 2=600 3=1200 4=2400 5=4800
6=9600 7=19200 8=38400 9=57600 10=115200 Baud.
ABaudRate UInt8 EXPERT RECONFIGURABLE  
comm.bufferFull Buffer Full
Buffer Full Notification.
ARxBufferFull Int16 EXPERT RECONFIGURABLE  
comm.dataFrame Data Frame
Data Frame: 1=7E1 2=7O1 3=8N1 4=8E1 5=8O1 9=7E2
10=7O2 11=8N2 12=8E2 13=8O2.
ADataFrame UInt8 EXPERT RECONFIGURABLE  
comm.enableRtsCts Enable RTS/CTS
Enable RTS/CTS
AEnableCTSRTS Bool EXPERT RECONFIGURABLE  
comm.enableXonXoffRx Enable XOn/XOff Rx
Enable XOn/XOff supported rx data
AEnableXOnXOffRx Bool EXPERT RECONFIGURABLE  
comm.enableXonXoffTx Enable XOn/XOff Tx
Enable XOn/XOff supported tx data
AEnableXOnXOffTx Bool EXPERT RECONFIGURABLE  
comm.resetUnitDummy resetDummy(do not touch)
please do not touch this value
AResetUnit UInt8 EXPERT RECONFIGURABLE  
comm.serialCheck Serial Check
Check serial protocol command value (reads back
string from command function window (ASerP
input value)
ASerCheck String EXPERT RECONFIGURABLE  
comm.serialStartCharacter Start Character
Serial message start character.
ASTX0 Char EXPERT RECONFIGURABLE  
comm.serialStopCharacter Stop Character
Serial message stop character.
AETX0 Char EXPERT RECONFIGURABLE  
controlMode Control Mode
Control Mode Selection 0=(setpoint = BUS
setpoint) 1=(setpoint = analog input)
2=(setpoint = master output(FLOW-BUS) * slave
factor(FLOW-BUS)) 3=(close valve) 4=(controller
idle (no reaction on changes in sensor signal))
5=(testmode enable (select subject with par
70)) 6=(tuningmode enable (select subtject with
par 79)) 7=(setpoint = 100%) 8=(purge valve
(fully open)) 9=(calibration mode enable
(select subject with par 58)) 10=(setpoint =
master output(analog in) * slave factor(FLOW-
BUS)) 11=(setpoint = keyboard OR FLOW-BUS
setpoint) 12=(setpoint = 0%) 13=(setpoint =
master output(FLOW-BUS) * slave factor(analog
in)) 14=((FPP) Range select mode) 15=((FPP)
Manual start sensor select, automatic end
sensor) 16=((FPP) Automatic start sensor
select, manual end sensor) 17=((FPP) Automatic
start and end sensor) 18=(setpoint = RS232
setpoint) 19=(RS232 broadcast mode) 20=(valve
stearing (valve = setpoint)) 21=(analog valve
stearing (valve = analog setpoint)) 22=(valve
safe state)
ACtrlMode UInt8 EXPERT RECONFIGURABLE  
customerModel Customer Model
Customer Model
ACustomerModel String EXPERT READONLY  
density Density
Density of selected fluid in kg/m3
ADensity Float EXPERT RECONFIGURABLE  
enableFifoCont Enable FIFO Cont.
Enable send FIFO data continuous
AFifoCont Bool EXPERT RECONFIGURABLE  
enableTransferOpt Enable Transfer Rate Opt.
Enable transfer rate optimization
ATransferOpt Bool EXPERT READONLY  
fSetpoint F set point
f set point
AfSetpoint Float EXPERT RECONFIGURABLE  
firmwareId Firmware ID
Firmware Identification number
AFirmwareID UInt8 EXPERT READONLY  
firmwareVersion Firmware Version
Firmware Version
AFirmwareVersion String EXPERT READONLY  
fluidName Fluid Name
Fluid Name
AFluidName String EXPERT RECONFIGURABLE  
fluidNumber Fluid Number
Fluid Number
AFluidNumber UInt8 EXPERT RECONFIGURABLE  
massFlow Mass flow
mass flow kg/min
AMassFlow Float EXPERT READONLY  
measure Measure
Measured value (100% = 32000)
AMeasure Int16 EXPERT RECONFIGURABLE  
measurementStatus Measurement Status
Measurement status
AMeasurementStatus Int16 EXPERT READONLY  
orifice Orifice
orifice diameter
AOrifice Float EXPERT RECONFIGURABLE  
pIOparamCapacity0 APIOparamCapacity0
PIO param Capacity 0
APIOparamCapacity0 Float EXPERT RECONFIGURABLE  
pIOparamCapacity100 APIOparamCapacity100
PIO param Capacity 100
APIOparamCapacity100 Float EXPERT RECONFIGURABLE  
powerMode Power Mode

APowerMode UInt8 EXPERT RECONFIGURABLE  
pressure Pressure
Pressure
APressure Float EXPERT RECONFIGURABLE  
pressureSensorType Pressure Sensor Type
Pressure Sensor Type : 0=(delta-P 0..5” W.C.)
1=(delta-P 0…10” W.C.) 2=(absolute pressure
800-1200 mbar) 3=(absolute pressure 800-1100
mbar) 4=(delta-P -5…0” W.C.) 5=(delta-P
-10…0” W.C.) 6=(delta-P -10…+10” W.C.)
7=(delta-P 0…1 PSI) 8=(delta-P -1…0 PSI)
10=(absolute pressure 0-10 bar)
APressureSensorType UInt8 EXPERT RECONFIGURABLE  
referenceVoltageFullScale Reference Voltage Full Scale
analog V ref. input correction factor full
scale (2000=1*multiplication)
ARefVoltInputFullScale Int16 EXPERT RECONFIGURABLE  
referenceVoltageZeroScale Reference Voltage Zero Scale
analog V ref. input corr. factor zero scale
(DSCM-A 0=0 other 32767=0)
ARefVoltInputZeroScale Int16 EXPERT RECONFIGURABLE  
resetInputSelection Reset Input Selection
Reset Input Selection
AResetInputSelection String EXPERT RECONFIGURABLE  
sensorInputFullScale Sensor Input Full Scale
analog sensor signal input correction factor
full scale (2000=1*multiplication)
ASensorInputFullScale Int16 EXPERT RECONFIGURABLE  
sensorInputZeroScale Sensor Input Zero Scale
analog sensor signal input corr. factor zero
scale (DSCM-A 0=0 other 32767=0)
ASensorInputZeroScale Int16 EXPERT RECONFIGURABLE  
sensorNumber Sensor Number
pointer to sensor number in calibration tube
(FPP)
ASensorNumber UInt8 EXPERT RECONFIGURABLE  
sensorType Sensor Type
Sensor Type 0=(pressure (controller))
1=(liquid volume (controller)) 2=(liquid/gas
mass (controller)) 3=(gas volume (controller))
4=(other sensor type (controller))
128=(pressure (sensor)) 129=(liquid volume
(sensor)) 130=(liquid/gas mass (sensor))
131=(gas volume (sensor)) 132=(other sensor
type (sensor))
ASensorType UInt8 EXPERT RECONFIGURABLE  
serialCommand Serial Command
Send serial protocol command.
ASerial String EXPERT RECONFIGURABLE  
serialNumber Serial Number
Serial Number
ASerialNumber String EXPERT READONLY  
serviceDate Service Date
Date of last service action
AServiceDate String EXPERT RECONFIGURABLE  
serviceNumber Service Number

AServiceNumber String EXPERT RECONFIGURABLE  
setPoint Set Point
Set Point (100% = 32000)
ASetpoint Int16 EXPERT RECONFIGURABLE  
temperature Temperature
Temperature
ATemperature Float EXPERT RECONFIGURABLE  
time Time
Time, maybe uptime, HW documentation unclear.
ATime Float EXPERT RECONFIGURABLE  
tuningMode Tuning Mode
Tuning Mode: 0=(idle; no action) 1=(sensor)
2=(valve) 3=(Fuzzy controller normal
operation) 4=(Fuzzy controller open at zero)
5=(PID controller)
ATuningMode UInt8 EXPERT RECONFIGURABLE  
resetManually reset
Write this property to Reset: 0=(no reset)
1=(reset counter value (no mode change) or
common reset) 2=(reset alarm) 3=(restart
batch counter) 4=(reset counter value (counter
off)) 5=(Reset module (soft reset))
AReset UInt8 ADMIN RECONFIGURABLE