Cluster flange¶
The LEMO connectior on the Smaract cluster flange view from outside is shown
in smaract-cluster-flange
. Connection 1 and 2 can be
identified as being the only outer pair symmetric with respect to a line
connection two opposite bolts.
Motor table for the flange facing upstream:
LEMO connector | Stage Motor | Positive direction |
---|---|---|
1 | guard upstream bottom blade Y1 | +Y |
2 | guard downstream right blade X1 | +X |
3 | guard upstream top blade Y2 | +Y |
4 | guard downstream left blade X2 | +X |
5 | reflectometer Y | -Y |
6 | reflectometer X | +X |
7 | THz X | +X |
8 | THz Z | +Z |
9 | THz Y | -Y |
10 | THz AY | +rY |
11 | THz AZ | +rZ |
12 | THz AX | -rX |
Motor table for the flange facing up:
LEMO connector | Stage Motor | Positive direction |
---|---|---|
1 | not connected | |
2 | not connected | |
3 | not connected | |
4 | not connected | |
5 | Diagnostic Ch. 1.1 X | -X |
6 | not connected | |
7 | not connected | |
8 | Diagnostic Ch. 1.2 Y1 (small) | +Y |
9 | TZPG X | -X |
10 | not connected | |
11 | Diagnostic Ch. 2.1 Y2 (big) | +Y |
12 | TZPG Y | +Y |